Evaluation of Environmental Cytotoxic Drug Contamination in a Clinical Setting

DVM, MS, DACVIM (Oncology) and
DVM
Article Category: Research Article
Page Range: 32 – 37
DOI: 10.5326/JAAHA-MS-6471
Save
Download PDF

ABSTRACT

The use of cytotoxic drugs to treat neoplastic conditions is increasing in veterinary practices. Many agents have the potential to be genotoxic and evidence of exposure to cytotoxic drugs has been found in healthcare workers handling these pharmaceuticals. To date, limited contamination evaluations have been performed in veterinary practices. Evaluation for carboplatin contamination was performed at a veterinary teaching hospital involving twelve areas in the dispensary and treatment room. Detectable levels of platinum were found on the surface of the biological safety cabinet where drugs are transferred from vial to administration device. Results indicate contamination did occur and care must be taken during all phases of cytotoxic drug preparation and administration; precautionary procedures must be in place to limit the spread of surface contamination and personnel exposure.

Introduction

Exposure to cytotoxic agents is documented in human healthcare personnel and has been evaluated by a variety of methods including urine mutagenicity assays; evaluation for chromosomal aberrations, DNA damage, and urinary metabolite levels of cytotoxic agents in healthcare personnel; and evidence of environmental contamination with various drugs.18 Many cytotoxic agents are known genotoxic agents with reports of acute symptoms such as vomiting, headaches, and dizziness; liver damage; reproductive deficits; and chromosomal aberrations.4,915 Lawson et al. recently reported a two-fold increased risk of spontaneous abortion before the twelfth week of gestation in nurses handling antineoplastic drugs.15 Aberrations in chromosomes 5, 7, and 11 were found in oncology nurses handling both alkylating and nonalkylating cytotoxic agents.4 The documented aberrations are consistent with those in individuals who develop acute myelogenous leukemia secondary to previous treatment with cytotoxic agents.4

Exposure routes of healthcare personnel include inhalation, dermal absorption, ingestion of contaminated food, mouth contact with contaminated hands, and accidental injection.16,17 Dermal absorption is the most likely route of exposure based on findings from previous studies.18,19 Guidelines to decrease personnel exposure to hazardous drugs have been developed by the National Institute for Occupational Safety and Health (NIOSH), the American Society of Health-System Pharmacists, and also the European College of Veterinary Internal Medicine of Companion Animals with the intent of minimizing occupational and environmental exposure to hazardous drugs.16,17,20 Additionally, in 2010, NIOSH released a Workplace Solutions document entitled “Safe Handling of Hazardous Drugs for Veterinary Healthcare Workers” to increase awareness of occupational risk associated with handling of hazardous drugs in veterinary medicine.21 Guidelines include the use of appropriate personal protective equipment (PPE) (such as protective gowns, double gloves, goggles, and respirator masks), the use of a biological safety cabinet (BSC) designed to prevent hazardous drugs from being released into the work environment, and also the use of a closed system drug transfer device (CSTD) designed to limit the potential for generating aerosols and exposing personnel to needles when transferring hazardous drugs.16,17,20

The aim of this study was to evaluate environmental contamination in a veterinary teaching hospital setting where cytotoxic agents are used on a regular basis. Based on frequency of use amongst cytotoxic drugs at the Kansas State University Veterinary Health Center (KSU VHC) and practicality in measurement, carboplatin was chosen to assess for environmental contamination.

Materials and Methods

Cytotoxic drug preparation was performed in a clinically dedicated, class II, type B2 BSC, which has 100% venting outside of the building. Additionally, a drug transfer deviceb was in use for administration of chemotherapy doses. Personal protective equipment used included a nonpermeable gown and two pairs of specified chemotherapy gloves for the dispensary personnel and a nonpermeable gown, single layer pair of chemotherapy gloves, and protective eyewear for administration personnel. Once the cytotoxic drug was transferred into the appropriate syringe for administration within the BSC, the transfer device for administration was attached to the syringe and the syringe placed into a small sealable bag. The outer gloves were removed by pharmacy personnel and the small bag was placed into a larger sealable bag outside of the BSC for transport to the chemotherapy administration area. Following administration, all disposables used for administration were packaged into the large outer transport bag for disposal, sealed, and placed in appropriate disposal containers.

For surface evaluation, wipe samples were obtained using the standardized sample kitsa. Two sample kits were obtained, each with material for six samples. Each kit contained 12 tissues (2 per site), 6 droppers with 17 mL 0.5 M hydrochloric acid (HCl) solution, 6 containers with labels and plastic mini bags for shipping, and 6 pairs of gloves. Twelve locations in the KSU VHC were assessed for platinum contamination: five locations within the dispensary and seven locations within the chemotherapy treatment area. The sizes of each location were measured and the areas were calculated in cm2. Samples were acquired according to manufacturer's instructions (Figure 1). In short, 17 mL of 0.5 M HCl solution was supplied in bottles with a dropper applicator for each sampling site. The entire 17 mL volume of HCl was applied to each designated surface using the dropper applicator. The solution was spread over the surface by the supplied tissue. This tissue was then placed in a container labeled with a description of the surface sampled. A second supplied tissue was then used to wipe the defined surface until dry and placed in the same container as the first. This procedure was performed for each designated surface. All samples were frozen after sampling and during transport until sample preparation and analysis. Platinum ions were measured instead of the platinum-containing drugs themselves. Platinum analysis was performed with stripping voltammetry according to standard procedures previously described.22 Samples were analyzed in duplicate and mean values were reported. Contamination was calculated in ng/cm2. Due to background levels of platinum, quantification limits were set at 0.50 ng/mL HCl.

Figure 1. Acquisition of wipe samples for evaluation of platinum contamination using the sample kita. (A) 30 × 30cm area was taped off and then 17 mL of 0.5M HCl was placed on the surface of the chemotherapy administration table. Arrow denotes the dropper bottle that was supplied in the kit containing the HCl solution. (B) The HCl solution was evenly distributed on the designated surface using the first wipe for this site. A second wipe was used to dry the designated area. (C) Both wipes were placed in the provided labeled container designated for this site. Arrow denotes the dropper bottle that contained the HCl solution for this site. (D) All containers were clearly labeled for each site and placed in a prelabeled container for shipping to the testing site. HCl, hydrochloric acid.Figure 1. Acquisition of wipe samples for evaluation of platinum contamination using the sample kita. (A) 30 × 30cm area was taped off and then 17 mL of 0.5M HCl was placed on the surface of the chemotherapy administration table. Arrow denotes the dropper bottle that was supplied in the kit containing the HCl solution. (B) The HCl solution was evenly distributed on the designated surface using the first wipe for this site. A second wipe was used to dry the designated area. (C) Both wipes were placed in the provided labeled container designated for this site. Arrow denotes the dropper bottle that contained the HCl solution for this site. (D) All containers were clearly labeled for each site and placed in a prelabeled container for shipping to the testing site. HCl, hydrochloric acid.Figure 1. Acquisition of wipe samples for evaluation of platinum contamination using the sample kita. (A) 30 × 30cm area was taped off and then 17 mL of 0.5M HCl was placed on the surface of the chemotherapy administration table. Arrow denotes the dropper bottle that was supplied in the kit containing the HCl solution. (B) The HCl solution was evenly distributed on the designated surface using the first wipe for this site. A second wipe was used to dry the designated area. (C) Both wipes were placed in the provided labeled container designated for this site. Arrow denotes the dropper bottle that contained the HCl solution for this site. (D) All containers were clearly labeled for each site and placed in a prelabeled container for shipping to the testing site. HCl, hydrochloric acid.
Figure 1 Acquisition of wipe samples for evaluation of platinum contamination using the sample kita. (A) 30 × 30cm area was taped off and then 17 mL of 0.5M HCl was placed on the surface of the chemotherapy administration table. Arrow denotes the dropper bottle that was supplied in the kit containing the HCl solution. (B) The HCl solution was evenly distributed on the designated surface using the first wipe for this site. A second wipe was used to dry the designated area. (C) Both wipes were placed in the provided labeled container designated for this site. Arrow denotes the dropper bottle that contained the HCl solution for this site. (D) All containers were clearly labeled for each site and placed in a prelabeled container for shipping to the testing site. HCl, hydrochloric acid.

Citation: Journal of the American Animal Hospital Association 53, 1; 10.5326/JAAHA-MS-6471

Results

In the 12 mo preceding evaluation, 73 doses (17,128mg total) of carboplatin had been prescribed and prepared by the KSU VHC dispensary (Figure 2). The areas sampled included five areas within the dispensary: (1) the surface of the BSC, (2) the floor in front of the BSC, (3) the drug storage container, (4) the refrigerator handle, and (5) the drug storage basin in the refrigerator where drugs are stored until they are ready for administration. Seven areas within the chemotherapy treatment room were sampled: (1) the door handle into the room, (2) the administration table, (3) the floor below the administration table, (4) the floor under the stand where syringes containing chemotherapy dosages are placed prior to administration and waste is packaged after administration, (5) the counter in the chemotherapy treatment room, (6) the door threshold into the secondary oncology room, and (7) the desk in the secondary oncology room. Results of wipe sample analysis are reported in Table 1. Assuming 100% recovery and wipe efficiency, all results are underestimates. Low-level contamination was found on the surface of the BSC. No other areas sampled showed evidence of platinum contamination.

Figure 2. Amount of carboplatin prescribed and prepared by the KSU VHC dispensary prior to contamination evaluation. A total of 17,128 mg was prescribed in 73 doses and is expressed on a per month basis for the 12 mo preceding evaluation. KSU VHC, Kansas State University Veterinary Health Center.Figure 2. Amount of carboplatin prescribed and prepared by the KSU VHC dispensary prior to contamination evaluation. A total of 17,128 mg was prescribed in 73 doses and is expressed on a per month basis for the 12 mo preceding evaluation. KSU VHC, Kansas State University Veterinary Health Center.Figure 2. Amount of carboplatin prescribed and prepared by the KSU VHC dispensary prior to contamination evaluation. A total of 17,128 mg was prescribed in 73 doses and is expressed on a per month basis for the 12 mo preceding evaluation. KSU VHC, Kansas State University Veterinary Health Center.
Figure 2 Amount of carboplatin prescribed and prepared by the KSU VHC dispensary prior to contamination evaluation. A total of 17,128 mg was prescribed in 73 doses and is expressed on a per month basis for the 12 mo preceding evaluation. KSU VHC, Kansas State University Veterinary Health Center.

Citation: Journal of the American Animal Hospital Association 53, 1; 10.5326/JAAHA-MS-6471

TABLE 1 Results of Environmental Contamination of Platinum at 12 Sites within a Veterinary Teaching Hospital
TABLE 1

BSC, biological safety cabinet; CTR, chemotherapy treatment room; ND, not detected (platinum < 0.50 ng/mL HCl).

Discussion

The results of this evaluation show platinum contamination on the drug preparation surface within the BSC. Although no evidence of platinum contamination was detected outside of the BSC, the significance of what was detected cannot be overlooked. Without strict guidelines for PPE and handling procedures in place, the contamination detected is a potential source for dissemination to other surfaces increasing the risk of exposure to veterinary personnel not properly protected. Cytotoxic drugs are prepared in many veterinary clinics on a daily basis without the use of a BSC, CSTD, or appropriate PPE. The use of such equipment, as outlined in the NIOSH guidelines, decreases the risk to personnel; however, if not used or if contaminated surfaces are used for other procedures, exposure to unprotected personnel is likely to occur. In the evaluation presented here, because strict handling guidelines were followed, the potential for dissemination of the contamination outside of the BSC was minimized as evidenced by the lack of platinum detected in other areas of the dispensary and chemotherapy administration room.

The amount of platinum detected in the current evaluation is comparable to what was detected in a previous veterinary study by Kandel-Tschiederer et al, but higher than a more recent evaluation by Janssens et al., although the amount of platinum handled was substantially higher in the current study than that by Janssens et al. and approximately 1.5 times that of Kandel-Tschiederer et al.23,24 In the study by Kandel-Tschiederer et al., a reduction in platinum contamination after the institution of the CSTDc was detected. Even at the final evaluation, which was 9 mo after instituting the CSTDc, however, contamination was still present on the surface of the BSC, but other areas with previous evidence of contamination showed no evidence of contamination at the 9 mo time frame.23 Janssens et al. also showed evidence of platinum contamination in six veterinary oncology centers and all of them had contamination on the surface of the workbench where drug was prepared, among other locations.24 In that study, surfaces were sampled at one time point and one of two types of drug transfer devicesb,c were used at the veterinary oncology centers, although information on which transfer device was used at the individual sites was not available. The specific PPE used in both of the aforementioned veterinary studies was not stated.23,24

According to the 2004 NIOSH guidelines for handling hazardous drugs, a CSTD is “a drug transfer device that mechanically prohibits the transfer of environmental contaminants into the system and the escape of hazardous drug or vapor concentrations outside of the system.”16 Multiple devices are commercially available, however, only two systems c,d fit the specific definition contained within the 2004 NIOSH guidelines. Both of these systemsc,d have dry connections and a mechanism by which they prevent air leakage into the environment during drug transfer. The drug transfer device used in the current studyb does not have a specific mechanism by which air leakage is prevented.

In the present study, we chose to evaluate for platinum contamination due to the frequency in which carboplatin was prescribed at our institution and also due to practicality in that evaluation for surface contamination of platinum was commercially available. The analytic method by which platinum was measured in the current study was stripping voltammetry. Other analytic methods described for measuring platinum include high-performance liquid chromatography and inductively coupled plasma mass spectrometry (ICP-MS).25,26 When considering the previously reported veterinary studies, stripping voltammetry and ICP-MS have been the methods used.23,24 Previously reported limit of quantification of platinum measurements for these two methods are 0.1 pg/cm2 for voltammetry and 0.05 pg/cm2 for ICP-MS.26,27 Given these two comparisons, the measurement in the present study may be an underestimation of actual contamination.

Evaluation for platinum contamination was measured at only one point in time in the present study. To the authors' knowledge, duration of platinum contamination has not previously been determined. The BSC and areas evaluated in the current study are dedicated for clinical use. Platinum agents would not have been handled within the hood that were not administered to clinical patients and, therefore, accounted for in the overall carboplatin amount dispensed and then administered within the oncology treatment area. In the previous veterinary study using similar analytic methods, platinum contamination was measured before and 3, 6, and 9 mo after the institution of a CSTD.23 During this time period there was reduction in the amount of platinum detected and two sites became negative for platinum contamination in the span of 3 mo suggesting that the duration of platinum contamination is less than 3 mo.23

Conclusion

Based on the evidence of contamination found in this evaluation and the two other veterinary studies, it is necessary that dedicated areas for cytotoxic drug preparation, preferably in a class II, Type B2 BSC, be available in veterinary clinics providing chemotherapy services. Additionally, PPE and CSTD should be utilized and strict guidelines for preparation, administration, and disposal must be in place to minimize the potential for spreading of surface contamination throughout the veterinary hospital and limiting exposure to cytotoxic agents by veterinary personnel. One can also not disregard the risk of exposure with contact of contaminated excrement, including urine and feces, in veterinary patients who have received cytotoxic agents. While the amount of exposure necessary to cause adverse effects is unknown, due to the known genotoxic nature of these medications, no amount of exposure should be considered safe, particularly with the risk of repeated, long-term exposure by veterinary healthcare personnel.

The authors would like to thank Paul Sessink at Exposure Control B.V. for testing of the wipe samples and Kenneth Harkin (of Kansas State University) for critical review of the manuscript.

REFERENCES

  • 1
    Falck K,
    Gröhn P,
    Sorsa M,
    et al.
    Mutagenicity in urine of nurses handling cytostatic drugs. Lancet1979;1 (
    8128
    ):12501.
  • 2
    Newman MA,
    Valanis BG,
    Schoeny RS,
    et al.
    Urinary biological monitoring markers of anticancer drug exposure in oncology nurses. Am J Public Health1994;84 (
    5
    ):8525.
  • 3
    Labuhn K,
    Valanis B,
    Schoeny R,
    et al.
    Nurses' and pharmacists' exposure to antineoplastic drugs: findings from industrial hygiene scans and urine mutagenicity tests. Cancer Nurs1998;21 (
    2
    ):7989.
  • 4
    McDiarmid MA,
    Rogers B,
    Oliver MS.
    Chromosomal effects of non-alkylating drug exposure in oncology personnel. Environ Mol Mutagen2014;55:36974.
  • 5
    Connor TH,
    DeBord DG,
    Pretty JR,
    et al.
    Evaluation of antineoplastic drugs exposure of health care workers at three university-based US cancer centers. J Occup Environ Med2010;52 (
    10
    ):101927.
  • 6
    Ramphal R,
    Bains T,
    Vaillancourt R,
    et al.
    Occupational exposure to cyclophosphamide in nurses at a single center. J Occup Environ Med2014;56 (
    3
    ):30412.
  • 7
    Connor TH,
    Anderson RW,
    Sessink PJ,
    et al.
    Surface contamination with antineoplastic agents in six cancer treatment centers in Canada and the United States. Am J Health-Syst Pharm1999;56:142732.
  • 8
    Connor TH.
    Hazardous anticancer drugs in health care. Environmental exposure assessment. Ann NY Acad Sci2006;1076:61523.
  • 9
    International Agency for Research on Cancer. Pharmaceutical drugs. IARC Monograph on the Evaluation of Carcinogenic Risks to Humans. Vol 100A. Lyon, France: International Agency for Research on Cancer;2012.
  • 10
    Valanis BG,
    Vollmer WM,
    Labuhn KT,
    et al.
    Association of antineoplastic drug handling with acute adverse effects in pharmacy personnel. Am J Hosp Pharm1993;50:45562.
  • 11
    Valanis BG,
    Vollmer WM,
    Labuhn KT,
    et al.
    Acute symptoms associated with antineoplastic drug handling among nurses. Cancer Nursing1993;16 (
    4
    ):28895.
  • 12
    Sotaniemi EA,
    Sutinen S,
    Arranto AJ,
    et al.
    Liver damage in nurses handling cytostatic agents. Acta Med Scand1983;214 (
    3
    ):1819.
  • 13
    Valanis B,
    Vollmer WM,
    Steele P.
    Occupational exposure to antineoplastic agents: self-reported miscarriages and stillbirths among nurses and pharmacists. J Occup Environ Med1999;41 (
    8
    ):6328.
  • 14
    Valanis B,
    Vollmer W,
    Labuhn K,
    et al.
    Occupational exposure to antineoplastic agents and self-reported infertility among nurses and pharmacists. J Occup Environ Med1997;39 (
    6
    ):57480.
  • 15
    Lawson CC,
    Rocheleau CM,
    Whelan EA,
    et al.
    Occupational exposures among nurses and risk of spontaneous abortion. Am J Obstet Gynecol2012;206:327.e18.
  • 16
    National Institute for Occupational Safety and Health. NIOSH Alert: Preventing occupational exposures to antineoplastic and other hazardous drugs in health care settings. DHHS (NIOSH) Pub. No. 2004-165.
    Cincinnati, Ohio
    :
    U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, NIOSH;
    2004.
  • 17
    American Society of Health-System Pharmacists. ASHP guidelines on handling hazardous drugs. Am J Health Syst Pharm2006;63:117293.
  • 18
    Sessink PJ,
    Van de Kerkhof MC,
    et al.
    Environmental contamination and assessment of exposure to antineoplastic agents by determination of cyclophosphamide in urine of exposed pharmacy technicians: is skin absorption an important exposure route? Arch Environ Health 1994;49:1659.
  • 19
    Kromhout H,
    Hoek F,
    Uitterhoeve R,
    e tal. Postulating a dermal pathway for exposure to antineoplastic drugs among hospital workers. Applying a conceptual model to the results of three workplace surveys. Ann Occup Hyg2000;44:55160.
  • 20
    European College of Veterinary Internal Medicine-Companion Animals. Preventing occupational and environmental exposure to cytotoxic drugs in veterinary medicine. Available at: http://www.ecvim-ca.org/guidelines. Accessed September 29,2017.
  • 21
    National Institute for Occupational Safety and Health. Workplace solutions: Safe Handling of Hazardous Drugs for Veterinary Healthcare Workers. DHHS (NIOSH) Pub. No. 2010-150.
    Cincinnati, Ohio
    :
    U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, NIOSH;
    2010.
  • 22
    Weber G,
    Messerschmidt J.
    Signal enhancement in adsorptive stripping voltammetry of Pt by forced convection during the measurement step. Anal Chim Acta2005;545 (
    2
    ):16672. 
  • 23
    Kandel-Tschiederer B,
    Kessler M,
    Schwietzer A,
    et al.
    Reduction of workplace contamination with platinum-containing cytostatic drugs in a veterinary hospital by introduction of a closed system. Vet Rec2010;166 (
    26
    ):8225.
  • 24
    Janssens T,
    Brouwers EEM,
    deVos JP,
    et al.
    Determination of platinum surface contamination in veterinary and human oncology centres using inductively coupled plasma mass spectrometry. Vet Comp Oncol2015Sep;13 (
    3
    ):30513.
  • 25
    Raghavan R,
    Burchett M,
    Loffredo D,
    et al.
    Low-level (PPB) determination of cisplatin in cleaning validation (rinse water) samples. II. A high-performance liquid chromatographic method. Drug Dev Ind Pharm2000;26:42940.
  • 26
    Brouwers EEM,
    Huitema ADR,
    Bakker EN,
    et al.
    Monitoring of platinum surface contamination in seven Dutch hospital pharmacies using inductively coupled plasma mass spectrometry. Int Arch Occup Environ Health2007;80:68999.
  • 27
    Schmaus G,
    Schierl R,
    Funck S.
    Monitoring surface contamination by antineoplastic drugs using gas chromatography-mass spectrometry and voltammetry. Am J Helath Syst Pharm2002;59:95661.

Footnotes

  1. Exposure Control B.V.; Wageningen, The Netherlands

  2. OnGuard Closed Medication System with Tevadaptor Components; B. Braun, Bethlehem, Pennsylvania

  3. PhaSeal; Becton, Dickinson and Company, Franklin Lakes, New Jersey

  4. EquaShield; EquaShield, LLC, Port Washington, New York

  5. BSC (biological safety cabinet) CSTD (closed system drug transfer device) HCl (hydrochloric acid) ICP-MS (inductively coupled plasma mass spectrometry) KSU VHC (Kansas State University Veterinary Health Center) NIOSH (National Institute for Occupational Safety and Health) PPE (personal protective equipment)
Copyright: © 2017 by American Animal Hospital Association 2017
Figure 1
Figure 1

Acquisition of wipe samples for evaluation of platinum contamination using the sample kita. (A) 30 × 30cm area was taped off and then 17 mL of 0.5M HCl was placed on the surface of the chemotherapy administration table. Arrow denotes the dropper bottle that was supplied in the kit containing the HCl solution. (B) The HCl solution was evenly distributed on the designated surface using the first wipe for this site. A second wipe was used to dry the designated area. (C) Both wipes were placed in the provided labeled container designated for this site. Arrow denotes the dropper bottle that contained the HCl solution for this site. (D) All containers were clearly labeled for each site and placed in a prelabeled container for shipping to the testing site. HCl, hydrochloric acid.


Figure 2
Figure 2

Amount of carboplatin prescribed and prepared by the KSU VHC dispensary prior to contamination evaluation. A total of 17,128 mg was prescribed in 73 doses and is expressed on a per month basis for the 12 mo preceding evaluation. KSU VHC, Kansas State University Veterinary Health Center.


Contributor Notes

Correspondence: mhigginb@vet.k-state.edu (M.L.H.)
  • Download PDF